Mostrar el registro sencillo del ítem
dc.contributor.author | Espíndola, D | |
dc.contributor.author | DeRuiter, RM | |
dc.contributor.author | Santibanez, F | |
dc.contributor.author | Dayton, PA | |
dc.contributor.author | Pinton, G | |
dc.date.accessioned | 2024-01-17T15:55:23Z | |
dc.date.available | 2024-01-17T15:55:23Z | |
dc.date.issued | 2020 | |
dc.identifier.uri | https://repositorio.uoh.cl/handle/611/789 | |
dc.description.abstract | Super-resolution ultrasound imaging relies on the sub-wavelength localization of microbubble contrast agents. By tracking individual microbubbles, the velocity and flow within microvessels can be estimated. It has been shown that the average flow velocity, within a microvessel ranging from tens to hundreds of microns in diameter, can be measured. However, a 2D super-resolution image can only localize bubbles with sub-wavelength resolution in the imaging plane whereas the resolution in the elevation plane is limited by conventional beamwidth physics. Since ultrasound imaging integrates echoes over the elevation dimension, velocity estimates at a single location in the imaging plane include information throughout the imaging slice thickness. This slice thickness is typically a few orders or magnitude larger than the super-resolution limit. It is shown here that in order to estimate the velocity, a spatial integration over the elevation direction must be considered. This operation yields a multiplicative correction factor that compensates for the elevation integration. A correlation-based velocity estimation technique is then presented. Calibrated microtube phantom experiments are used to validate the proposed velocity estimation method and the proposed elevation integration correction factor. It is shown that velocity measurements are in excellent agreement with theoretical predictions within the considered range of flow rates (10 to 90 mu l/min) in a microtube with a diameter of 200 mu m. Then, the proposed technique is applied to two in-vivo mouse tail experiments imaged with a low frequency human clinical transducer (ATL L7-4) with human clinical concentrations of microbubbles. In the first experiment, a vein was visible with a diameter of 140 mu m and a peak flow velocity of 0.8 mm s(-1). In the second experiment, a vein was observed in the super-resolved image with a diameter of 120 mu m and with maximum local velocity of 4.4 mm s(-1). It is shown that the parabolic flow profiles within these micro-vessels are resolvable. | |
dc.description.sponsorship | National Institute of Health(United States Department of Health & Human ServicesNational Institutes of Health (NIH) - USA) | |
dc.relation.uri | http://dx.doi.org/10.1088/2057-1976/ab7f26 | |
dc.subject | ultrasound imaging | |
dc.subject | super-resolution | |
dc.subject | blood flow | |
dc.title | Quantitative sub-resolution blood velocity estimation using ultrasound localization microscopy ex-vivo and in-vivo | |
dc.type | Artículo | |
uoh.revista | BIOMEDICAL PHYSICS & ENGINEERING EXPRESS | |
dc.identifier.doi | 10.1088/2057-1976/ab7f26 | |
dc.citation.volume | 6 | |
dc.citation.issue | 3 | |
dc.identifier.orcid | Santibanez, Francisco/0000-0002-6959-4148 | |
uoh.indizacion | Web of Science |
Ficheros | Tamaño | Formato | Ver |
---|---|---|---|
No hay ficheros asociados a este ítem. |
El Repositorio Académico de la Universidad de O'Higgins es una plataforma de difusión documental que recopila, respalda y difunde la producción científica y académica de nuestra casa de estudios. En su interfaz, se integran diferentes tipos de documentos, tales como, libros, artículos académicos, investigaciones, videos, entre otros, los cuales pueden ser difundidos y utilizados con fines académicos y de investigación.
Los recursos contenidos en el repositorio son de libre acceso en texto completo, a excepción de aquellos que por restricciones propias del Derecho de Autor o por petición expresa de la autoría principal, no pueden ser difundidos en la condición mencionada.