| dc.contributor.author | Xavier, A | |
| dc.contributor.author | Alarcón, H | |
| dc.contributor.author | Espíndola, D | |
| dc.date.accessioned | 2024-01-17T15:54:08Z | |
| dc.date.available | 2024-01-17T15:54:08Z | |
| dc.date.issued | 2022 | |
| dc.identifier.uri | https://repositorio.uoh.cl/handle/611/371 | |
| dc.description.abstract | Localization plays a significant role in the production of ultrasound localization microscopy images. For instance, detecting more microbubbles reduces the time of acquisition, while localizing them more accurately improves the resolution of the images. Previous approaches to compare the multiple localization algorithms rely on numerical simulation of a single steady microbubble, with or without modeling its nonlinear response. In real-life situations, vessels have a nonconstant velocity profile, which creates relative movement, producing dynamically overlapped microbubbles even at low concentrations. These complexities deteriorate the behavior of the localization algorithms. To incorporate these effects on the characterization of the localization methods, we designed a virtual medium containing four microtubes of different inner diameters, where single-pixel microbubbles were allowed to flow within each microtube with a parabolic velocity profile. A finite difference method was used to simulate the propagation of ultrasound waves to obtain B-mode images that fed four direct microbubbles localization algorithms (i.e., weighted centroid, 2D-spline interpolation, parabolic fitting, and onset detection). The performance of these methods was quantified using the number of microbubbles detected, the microbubbles distribution, the full width at half maximum, the maximum velocity, and the computational time as metrics. Our simulation results suggest that 2D-spline and paraboloid fitting were the best methods, detecting 100% of the microbubbles with an error in their distribution of 249 and 244 microbubbles, respectively. Both methods with a computational time cost of 18% and 7% lower than weighted centroid, respectively. We also present an experimental comparison of these localization methods, finding results similar to the numerical ones. | |
| dc.description.sponsorship | Agencia Nacional de Investigacion y Desarrollo (ANID) through the Fondo Nacional de Desarrollo Cientifico y Tecnologico (FONDECYT) | |
| dc.description.sponsorship | Fondo Multidisciplinario UOH | |
| dc.relation.uri | http://dx.doi.org/10.1109/ACCESS.2022.3173308 | |
| dc.subject | Location awareness | |
| dc.subject | Ultrasonic imaging | |
| dc.subject | Superresolution | |
| dc.subject | Numerical models | |
| dc.subject | Standards | |
| dc.subject | Splines (mathematics) | |
| dc.subject | Radio frequency | |
| dc.subject | FullWave simulations | |
| dc.subject | localization algorithms | |
| dc.subject | microvessel imaging | |
| dc.subject | ultrasound localization microscopy | |
| dc.subject | ultrasound super-resolution | |
| dc.title | Characterization of Direct Localization Algorithms for Ultrasound Super-Resolution Imaging in a Multibubble Environment: A Numerical and Experimental Study | |
| dc.type | Artículo | |
| uoh.revista | IEEE ACCESS | |
| dc.identifier.doi | 10.1109/ACCESS.2022.3173308 | |
| dc.citation.volume | 10 | |
| dc.identifier.orcid | Xavier, Aline/0000-0001-6793-341X | |
| dc.identifier.orcid | Espindola, David/0000-0001-6675-9560 | |
| uoh.indizacion | Web of Science |
| Files | Size | Format | View |
|---|---|---|---|
|
There are no files associated with this item. |
|||
The Academic Repository of the University of O'Higgins is a documentary dissemination platform that collects, supports and disseminates the scientific and academic production of our university. In its interface, different types of documents are integrated, such as books, academic articles, research, videos, among others, which can be disseminated and used for academic and research purposes.
The resources contained in the repository are freely accessible in full text, except for those that due to restrictions of Copyright or by express request of the main author, cannot be disseminated in the aforementioned condition.